跳转到主内容

控制器升级后无法执行接管

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • 控制器硬件升级(机头交换)

问题描述

  • 控制器升级(机头交换)到新硬件平台已完成( 个节点)
  • 两个节点均已成功升级、集群应用程序已联机、但在启动第二个节点后、storage failover show会指示错误:
CLUSTER::*> storage failover show
                Takeover
Node       Partner     Possible State Description
-------------- -------------- -------- -------------------------------------
FAS01      FAS02      false   Waiting for FAS02, Takeover
                    is not possible: Storage failover
                    mailbox disk state is invalid,
                    Storage failover is disabled on the
                    partner node, Storage failover
                    interconnect error, NVRAM log not
                    synchronized, Disk inventory not
                    exchanged
FAS02      FAS01      false   Waiting for FAS01, Takeover
                    is not possible: Storage failover
                    interconnect error, NVRAM log not
                    synchronized, Disk inventory not
                    exchanged