跳转到主内容

共享和已分配SwitchtoShelter_Alert

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AF/ FAS
  • N9K-C9336C-FX2

问题描述

  • 已从集群中的所有磁盘架报告以下运行状况警报:

Node: Node1 Alert ID: SharedandDedicatedSwitchtoShelf_Alert
Resource: Shelf UUID: XX76889639XXXXXXXXXX
Severity: Major Indication
Time: Thu Mar 21 15:13:05 2024
Suppress: false Acknowledge: false
Probable Cause: Shelf 6.20 is connected to both shared and dedicated storage switches.
Possible Effect: This configuration is not supported.
Corrective Actions:
  1. Consult the guides that apply to your NVMe shelf and shared switch to review the cabling rules for your system.
  2. Connect shelf 6.20 only through either shared or dedicated storage switches.

  • 此外、还会同时发出以下运行状况警报:

Node   Node1
Monitor   node-connect
Alert ID   SharedAndDedicatedSwitchToHA_Alert
Alerting Resource   Node1
Subsystem   SAS-connect
Indication Time   Wed Mar 19 09:58:12 2025
Perceived Severity   Major
Probable Cause   Cable_tamper
Description   Controller "Node1" is connected to both shared switch "switch01" and dedicated storage switch "switch02". This configuration is not supported.
Corrective Actions   1. Consult the guide "Setup and configuration guide for Cisco shared switches" to review the cabling rules for your system.
2. Connect controller Node1 to NVMe shelves only through either shared or dedicated storage switches.
Possible Effect   Cluster network connectivity will be lost if shared switch switch01 fails.
Acknowledge   false
Suppress   false
Policy   SharedAndDedicatedSwitchToHA_Policy
Acknowledger   
Suppressor   
Additional Information   Switches: switch01, switch02
Shelves: 5.2, 5.3, 5.1
Initiator Ports: -
Port Connections: e5a::switch01:Ethernet1/12, e5b::switch02:Ethernet1/12
Alerting Resource Name   Node Node1
Additional Alert Tags   quality_of_service

  • 确认是否已按照NetApp建议为磁盘架端口布线。
  • 验证交换机和集群交换机的RC框架 文件和端口连接。