跳转到主内容

SAS端口已禁用PHY

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • 串行连接SCSI (SAS)

问题描述

  • SAS端口显示琥珀色LED
  • 中的SAS端口PHY已禁用警报 system health alert show

Clutser1::> system health alert show
               Node: Node1
           Resource: Port 0b
           Severity: Major
    Indication Time: Fri Jan 03 01:07:42 2020
           Suppress: false
        Acknowledge: false
     Probable Cause: SAS port 0b on controller Node1 has 1 disabled
                    PHYs.
    Possible Effect: Inactive PHYs might cause degraded link performance.
Corrective Actions: 1. Verify that SAS port 0b has disabled PHYs by using the "storage port show -node Node1 -port 0b" command.
                     2. If the disk shelves connected to port 0b have multiple path to the node, reset port 0b by using the (privilege: advanced) "storage port reset -node Node1 -port 0b" command.
                     3. Verify that the physical cable connection is secure and operational. If the disk shelves are multipathed, reseat the cable.
                     4. If the connected disk shelf is multipathed, replace
                     the SAS cable.

  • 已在中禁用PHY sysconfig -a

slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
        Firmware rev:       03.08.09.00
        Base WWN:           5:00a098:003abb6:34
        Phy State:         [4] Disabled
                            [5] Enabled, 12.0 Gb/s
                            [6] Enabled, 12.0 Gb/s
                            [7] Enabled, 12.0 Gb/s

 

  • EMS日志报告错误:

ERROR sasmon.adapter.phy.disable: Phy 14 of HBA 0a will be disabled due to excessive number of running disparity errors.


ERROR sasmon.adapter.phy.disable: Phy 2 of HBA 0a will be disabled due to burst of invalid dword errors.

注: 问题描述可能出现在连接的另一端(即IOM)

  • Cluster::*> storag shelf show -shelf 6.76

(...)
SAS Ports:
                                      -- Port Speeds Gb/s -- Power  Port
Phy # IOM Port Type WWPN              Operational Negotiated Status Status
----- --- --------- ----------------- ----------- ---------- ------ -----------
(...)
    8  B  Host      500a098007d72e84         12.0          - -      Enabled
    9  B  Host      500a098007d72e84         12.0          - -      Enabled
   10  B  Host      500a098007d72e84         12.0          - -      Enabled
   11  B  Host      500a098007d72e84            -          - -      phy_dis_inval_dword

  • Cluster::*> event log show -node node2|node1 -event *ds.sas*

Time                Node      Severity      Event
------------------- ------ ------------- ---------------------------
5/2/2022 12:18:22   node2     ALERT         ds.sas.hostphy.disableErr: Port [HST2] on channels 9d shelf ID 76 IOM B disabled due to excessive invalid dword error.
5/2/2022 12:17:46   node2     DEBUG         ds.sas.running.disparity: [HST2] on channels 9d shelf ID 76 IOM B bay - reports running disparity errors.
5/2/2022 12:15:40   node2     DEBUG         ds.sas.running.disparity: [HST2] on channels 9d shelf ID 76 IOM B bay - reports running disparity errors.
5/2/2022 12:15:04   node2     DEBUG         ds.sas.running.disparity: [HST2] on channels 9d shelf ID 76 IOM B bay - reports a running

 

 