跳转到主内容

由于 SAS 电缆故障,SAS 端口关闭

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

  • ONTAP 9
  • FAS9500
  • 存储配置为 Quad-path

问题描述

  • SYSCONFIG -A 报告 SAS 端口关闭:

slot 2: SAS Host Adapter 2c (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>)

  • EMS 报告 DISK REDUNDANCY FAILED 错误:

[node01: pmcsas_admin_0: sas.port.down:debug]: SAS port "2c" went down.
[node01: pmcsas_admin_0: sas.cable.pulled:debug]: Cable attached to SAS port "2c" was pulled out.
[node01: svc_queue_thread: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage
[node01: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • 环境报告外部货架仍然能够读取 SAS 电缆信息:

Channel: 11b
Shelf: 50

SAS cable information by element:
[1] Vendor: Amphenol
Type: MINI-SAS HD passive copper 5m ID: 00 Swaps: 0
Serial number: xxxxxxxxxx Part number: 112-00439+A0

  • 这篇文章对您有帮助吗?