跳转到主内容

系统故障 LED 亮起,并且反复报告 P3V3_BATP 传感器错误

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • FAS2520
  • FAS27XX
  • AF-C190
  • AF-A220
  • AF-A700

问题描述

  • 系统故障LED指示灯亮起。
  • 可以在以下命令输出中找到P3V3_Batt错误事件。

cluster::> system controller service-event show

Node             ID  Event Location                      Event Description
---------------- --- ----------------------------------  ----------------------
node     1   Controller B on Chassis 1          P3V3_BATT: Voltage Sensor 26 UNC

  • BMC ""system fru led show all显示故障LED已由BMC设置为ON。

BMC node> priv set diag
BMC node*> system fru led show all
FRU LED ID 1 is off
FRU LED ID 2 is on. Set by BMC
FRU LED ID 3 is on
FRU LED ID 4 is on

  • P3V3_Batt传感器错误在BMC ""events all输出中重复报告。
Record 903: Wed Mar 18 01:52:39.930000 2020 [IPMI.notice]: 0100 | 02 | EVT: 8157bbbd | P3V3_BATT | Deassertion Event, "Upper Non-critical going high" | Reading: 3.272 | Threshold: 3.307
Record 904: Wed Mar 18 02:14:02.350000 2020 [IPMI.notice]: 0001 | 02 | EVT: 0157bdbd | P3V3_BATT | Assertion Event, "Upper Non-critical going high" | Reading: 3.307 | Threshold: 3.307
Record 905: Wed Mar 18 04:22:52.940000 2020 [IPMI.notice]: 0002 | 02 | EVT: 8157bbbd | P3V3_BATT | Deassertion Event, "Upper Non-critical going high" | Reading: 3.272 | Threshold: 3.307
Record 906: Wed Mar 18 04:44:27.430000 2020 [IPMI.notice]: 0003 | 02 | EVT: 0157bdbd | P3V3_BATT | Assertion Event, "Upper Non-critical going high" | Reading: 3.307 | Threshold: 3.307
 
 
Record 1945: Sun May 29 23:44:05 2022 [IPMI.notice]: 6401 | 02 | EVT: 8150bfbd | Bat_3.0V | Deassertion Event, "Lower Non-critical going low "
Record 1946: Sun May 29 23:44:14 2022 [IPMI.notice]: 6501 | 02 | EVT: 0150bdbd | Bat_3.0V | Assertion Event, "Lower Non-critical going low "
Record 1947: Sun May 29 23:44:16 2022 [IPMI.notice]: 6601 | 02 | EVT: 0301ffff | Controller_Fault | Assertion Event, "State Asserted"
Record 1948: Mon May 30 00:43:26 2022 [IPMI.notice]: 6701 | 02 | EVT: 0300ffff | Controller_Fault | Assertion Event, "State Deasserted"