跳转到主内容

温度过高会导致磁盘架故障警报

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF / ASA / FAS
  • DS2246
  • ONTAP 9

问题描述

  • EMS log 显示SHELF_FAULT 错误:
 
 [FAS-01: dsa_worker0: ses.status.temperatureWarning:alert]: DS2246 (S/N XXXXXXXXXXX) shelf 5 on channel 0b temperature warning for Temperature sensor 6: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower right power supply.
 [FAS-01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
 [FAS-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
 
 
  • STORAGE-FAULT ASUP日志:

Enclosure Status: non-critical
Channel: 0b
Shelf: 5
Shelf Type: DS2246

...

Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,36,00  
  2: OK                01,00,3A,00  
  3: OK                01,00,3D,00  
  4: OK                01,00,53,00  
  5: OK                01,00,3C,00  
  6: NONCRITICAL       03,00,56,04  OT WARNING
  7: OK                01,00,3E,00  
  8: OK                01,00,3F,00  

 

  • ENVIRONMENT ASUP日志:

安装了温度传感器的元件列表:1、2、3、4、5、6、7、8;错误   :6
主机架温度:
    [1] 34 C (93 F)(环境     )正常温度范围[2] 38
C (100             F)正常温度范围[3] 41 C (105
F) 正常温度范围[4] 63 C (145 F)正常温度范围-------温度传感器温度范围中的104-            (104
F- 104-)温度范围
中的温度传感器
------------> PSU2中的传感器
    [7]41 C (105 F) 正常温度范围[8]42 C (107 F)正常温度范围
     
 

  • DC环境中没有过温。
  • 磁盘架固件已升级到最新版本。