跳转到主内容

节点因电池剩余容量严重不足警报而重启

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

  • AFF-C30
  • ONTAP 9

问题描述

  • 事件日志中报告了以下电池警报:
[Node-01: env_mgr: nvmem.battery.capLow:alert]: The NVMEM battery capacity is low (1 cycles).
[Node-01: env_mgr: nvmem.battery.fccLowCrit:EMERGENCY]: The NVMEM battery full-charge capacity is critically low (15 ). To prevent data loss, the system will shut down in 20 minutes.
[Node-01: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (remain capacity critical low) WARNING.
[Node-01: env_mgr: callhome.battery.failure:EMERGENCY]: Call home for BATTERY (full capacity critical low) CRITICAL.
[Node-01: statd: monitor.nvramLowBattery:EMERGENCY]: NVRAM battery is dangerously low.
[Node-01: statd: monitor.nvramLowBattery.notice:notice]: If the NVRAM battery is dangerously low, the system shuts down automatically every 24 hours to encourage you to replace it. If you reboot the system it will run for another 24 hours before shutting down.
[Node-01: statd: callhome.battery.low:alert]: Call home for BATTERY_LOW.
[Node-01: statd: monitor.shutdown.nvramLowBattery.pending:alert]: NVRAM battery is dangerously low. Halting system in 24 hours. Replace the battery immediately!
  • 如果未采取任何操作,则节点每 24 小时重新启动一次,并显示以下事件:

[Node-01: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (BATTERY (full capacity critical low) for 20 mins)

[Node-01: env_mgr: nvmem.battery.capNormal:notice]: The NVMEM battery capacity is normal.
[Node-01: statd: monitor.nvramLowBattery:EMERGENCY]: NVRAM battery is dangerously low.
[Node-01: statd: monitor.nvramLowBattery.notice:notice]: If the NVRAM battery is dangerously low, the system shuts down automatically every 24 hours to encourage you to replace it. If you reboot the system it will run for another 24 hours before shutting down.
[Node-01: statd: callhome.battery.low:alert]: Call home for BATTERY_LOW.

  • 自动支持 SP-LATEST-IPMI 部分中的传感器报告以下内容:

======================================
hsamcmd --fault-show-all
===============================
tag  origin  fld                    fault reason                   count  time             
---- ------- ----                   -------------                   ------ -----            
1   bmc    /chassis-1/controller-a/nvbatt-1     Bat_Rem_Cap: Current Sensor 94 LNC        1    Sat Jul 19 23:25:29 2025
2   bmc    /chassis-1/controller-a/nvbatt-1     Bat_Rem_Cap: Current Sensor 94 LCR        1    Sat Jul 19 23:25:29 2025
3   bmc    /chassis-1/controller-a/nvbatt-1     Bat_Full_Cap: Current Sensor 95 LNC        1    Sat Jul 19 23:25:29 2025
4   bmc    /chassis-1/controller-a/nvbatt-1     Bat_Full_Cap: Current Sensor 95 LCR        1    Sat Jul 19 23:25:29 2025
5   bmc    /chassis-1/controller-a/nvbatt-1     Bat_Dstg_Cycles: Battery Sensor 99 Fault     2    Sat Jul 19 23:25:29 2025

Fault Lights On:
       /chassis-1                                        6    
       /chassis-1/controller-a                                  6    
       /chassis-1/controller-a/nvbatt-1                             6    

 

Sensor Name        State      Current   Critical    Warning    Warning   Critical
                     Reading     Low      Low      High     High
-------------------------------------------------------------------------------------------------

Bat Design Cap       normal      10500 W*hr    --      --      --      --     
Bat Dstg Cycles     critlow      1 cycles   2 cycles   3 cycles   --      --     
Bat Cycle Count      normal        3 cycles   --      --      --      450 cycles
Bat FRU LED                 OFF
Battery Charge Failed?           FALSE
Battery Charge Bad?           TRUE
Battery Capacity Message         BAD
Battery RemCap Desc            READY
          
NV0 Battery State            FULLY_DISCHARGED
NV0 Battery Voltage    normal      8150 mV    5500 mV    5750 mV    8300 mV    8500 mV   

Battery Charge               BAD