跳转到主内容

NS224 风扇出现故障

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

NS224盘架

问题描述

  • 由于风扇故障,NS224 磁盘架状态处于严重状态:
::> system node run -node <node> -command storage show fault
Fans:
Element Status     Status Bytes  Status Descriptions
  1: OK         01,07,FF,26  
  2: OK         01,07,FF,26  
  3: OK         01,07,FF,26  
  4: OK         01,07,FF,26  
  5: OK         01,07,FF,26  
  6: OK         01,07,FF,27  
  7: OK         01,07,FF,27  
  8: CRITICAL      02,07,FF,27  
  9: OK         01,07,FF,27  
 10: OK         01,07,FF,27
  • 事件日志中会报告以下警报:

8/18/2025 10:37:00 node1 EMERGENCY monitor.globalStatus.critical: Disk shelf fault.

8/18/2025 10:00:00 node1 ALERT monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.

  • 更换风扇,显示错误跟随有故障的风扇。