适用场景

  • AFF A800
  • 运行FW 0140或更低版本的FS4483PSM3E内部磁盘架模块。

问题描述

  • 为内部磁盘架模块报告了间歇性错误:
[node_name: dsa_worker5: ses.status.electronicsWarn:error]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s environmental monitoring warning for SES electronics 2: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the bottom, on shelf module (B).
[node_name: dsa_worker5: ses.status.electronicsInfo:info]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s environmental monitoring information for SES electronics 2: normal status.
 
[node_name: dsa_worker1: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch error for PCI Switch 1: status not available; status not available. This element is on the rear of the shelf at the top, on shelf module (A).
[node_name: dsa_worker1: ses.status.ModuleInfo:info]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch information for PCI Switch 1: normal status.
  • 所有错误消息均会自动清除(正常)、无需(手动)干预
  • 清除这些消息时无模式
  •  由于这些消息、未发现其他影响或问题描述