跳转到主内容

IOM状态未知

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

DS2246

问题描述

storage show fault -v 输出中的IOMA状态未知
Enclosure Status: information
Channel: 0d
Shelf: 31
Shelf Type: DS2246
Product Serial Number: SHFFG1913000003
Module Type: IOM6
 
Enclosure Electronics:
Element Status     Status Bytes  Status Descriptions
1 [IOM6 A]   : UNKNOWN      06,00,00,00
2 [IOM6 B]   : OK         01,00,01,80  REPORT
 
SAS Connectors:
Element Status     Status Bytes  Status Descriptions
1: UNKNOWN      06,00,FF,00
2: UNKNOWN      06,00,FF,00
3: OK         01,03,FF,00
4: OK         01,03,FF,00
 
Vendor Unique Element 83-IOM6: (SAS)
Element Status     Status Bytes  Status Descriptions
1 [IOM6 A]   : UNKNOWN      06,00,00,00
2 [IOM6 B]   : OK         01,08,00,20  MASTER, RESERVED
 
Vendor Unique Element 85-IOM6: (ACP)
Element Status     Status Bytes  Status Descriptions
1 [IOM6 A]   : UNKNOWN      06,10,00,80
2 [IOM6 B]   : OK         01,10,00,80
 
Vendor Unique Element 8B-IOM6: (ETHERNET)
Element Status     Status Bytes  Status Descriptions
1 [IOM6 A]      : UNKNOWN      06,01,00,00
2 [IOM6 B]      : OK         01,00,00,00
 
Temperature Sensors:
Element Status     Status Bytes  Status Descriptions
1: OK         01,00,28,00
2: OK         01,00,2C,00
3: OK         01,00,2C,00
4: OK         01,00,40,00
5: OK         01,00,2C,00
6: OK         01,00,41,00
7: UNKNOWN      06,00,2E,00
8: OK