跳转到主内容

FAS 9500报告多个PSU缺失

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • FAS 9500

问题描述

  • 在BMC日志
    记录1149中调用并清除了针对各种传感器的虚假警报:Tue May 0911:07:41.712563 2023 [IPMI.notice]: Error Esting IPMI session:6.
    02c4 | 02 | EVT: 6f02ffff | Sensor 116 | Assertion Event, "Fault"
    Record 1150: Tue May 09 11:07:41.714562 2023 [IPMI.notice]: Error establishing IPMI Session : 6
    02c5 | 02 | EVT: 6f04ffff | Sensor 116 | Assertion Event, "Power Good"
    Record 1151: Tue May 09 11:07:41.726061 2023 [IPMI.notice]: Error establishing IPMI Session : 6
    02c6 | 02 | EVT: 6f02ffff | Sensor 117 | Assertion Event, "Fault"
    Record 1152: Tue May 09 11:07:41.727405 2023 [IPMI.notice]: Error establishing IPMI Session : 6
    02c7 | 02 | EVT: 6f04ffff | Sensor 117 | Assertion Event, "Power Good"
    Record 1153: Tue May 09 11:07:41.745122 2023 [IPMI.notice]: Error establishing IPMI Session : 6
    02c8 | 02 | EVT: 6f02ffff | Sensor 118 | Assertion Event, "Fault"
    Record 1154: Tue May 09 11:07:41.746583 2023 [IPMI.notice]: Error establishing IPMI Session : 6
    02c9 | 02 | EVT: 6f04ffff | Sensor 118 | Assertion Event, "Power Good"
  • 与此消息类似的AutoSupport消息可能已收到
    HA组通知(机箱电源降级:电源状态严重:PSU2、PSU4)。 错误
  • 日志甚至会显示发出警报消息的确切时间
    callhome.hm.alert.critical: Call home for Health Monitor process cphm: CriticalFruMultiFaultAlert[031820002882].