环境原因停机(电池组无效)

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

FAS8300

问题描述

  • 紧急停机并说明原因 Battery pack invalid
Jun 21 07:10:06 [krsl06nfc2-02:nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Pack Invalid' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.


Jun 21 07:11:06 [krsl06nfc2-02:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Pack Invalid' unreadable) CRITICAL.

Jun 21 07:17:06 [krsl06nfc2-02:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery pack invalid)

Waiting for PIDS:  1084.

Terminated

.

Uptime: 102d17h42m31s

FM halt: Time 8876489612 ms, 22709097543240426 cycles

 

System powering down.
  • 电池组状态:
Bat_Dsg_FET_Flt  | 0x0        | discrete   | 0x0480| na        | na        | na        | na        | na        | na
Bat_Chg_FET_Flt  | 0x0        | discrete   | 0x0480| na        | na        | na        | na        | na        | na
Bat_Pack_Invalid | na         | discrete   | na    | na        | na        | na        | na        | na        | na
Bat_Lrn_Active   | 0x0        | discrete   | 0x0180| na        | na        | na        | na        | na        | na
  • 问题描述在控制器通电后仍然存在