跳转到主内容

磁盘架温度警告

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • FAS/AFA
  • 磁盘架

问题描述

  • 从事件日志中、我们可以看到报告了以下磁盘架警告:

[node2: dsa_worker3: ses.status.temperatureWarning:alert]: DS2246 (S/N SHFFG1451XXXXXX) shelf 11 on channel 0c temperature warning for Temperature sensor 4: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower left power supply.
[node2: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[node2: dsa_worker4: ses.status.temperatureInfo:info]: DS2246 (S/N SHFFG1451XXXXXX) shelf 11 on channel 0c temperature information for Temperature sensor 4: normal status.

  • 传感器的位置映射到PSU。
  • 即使在更换PSU后、问题描述仍然存在。
  •   磁盘架日志指示 仅通过 磁盘架的IOM B设置和清除这些警告 

--------------------------------------------------------------
Shelflog start time: Tue Jan  9 05:01:59 GMT 2024
Controller Id: 536XXXXXX
Channel: 0a Shelf: 10 Module type: IOM6 Firmware rev: 0200
Shelf product id: DS224IOM6
Shelf Serial Number: SHFFG145XXXXXX
Module B Serial Number: 7904XXXXXX
Log ID: SHFFG1450000251_B_7f
Timestamp: Wed Feb 14 02:43:31 IST 2024
--------------------------------------------------------------
EVENT LOGS
Timestamp Tue Feb 13 21:13:32 2024 (2812 10:40:01.901)
Tue Feb 13 21:13:23 2024 ( 2812 10:39:53.292); 0304002D; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: warning hot set
Tue Feb 13 21:13:24 2024 ( 2812 10:39:54.361); 0304002E; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: warning hot cleared
Tue Feb 13 21:13:24 2024 ( 2812 10:39:54.361); 03040031; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: OK
Tue Feb 13 21:13:25 2024 ( 2812 10:39:55.433); 0304002D; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: warning hot set
Tue Feb 13 21:13:30 2024 ( 2812 10:39:59.716); 0304002E; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: warning hot cleared
Tue Feb 13 21:13:30 2024 ( 2812 10:39:59.716); 03040031; M; ENC_MGT; env_control; 04; Temperature zone 3 is now: OK

 