跳转到主内容

磁盘缺失 - AutoSupport 消息

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ClusterA-01 中的 HA 组通知(缺少文件系统磁盘)错误
  • ClusterA-01 中的 HA 组通知(缺少备用磁盘)错误
  • Data ONTAP 8 7-模式
  • ONTAP 9
  • raid.disk.missing:info

事件摘要

每当 ONTAP 检测到已分配给节点的驱动器不再存在时,都会发送磁盘缺失 AutoSupport 消息。

验证

  • 事件日志将报告缺少的驱动器的详细信息:

event log show -severity INFORMATIONAL -event *filesystem.disk.missing*

Mon Apr 06 18:36:20 UTC [Nodename: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr1/plex0/rg3/0b.04.22 Shelf 4 Bay 22 [NETAPP   X477_SMBPE04TA07 NA00] S/N [XX1234567] UID [5000C500:AE235FDF:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.

Mon Apr 06 18:37:00 UTC [Nodename: config_failed_disk: callhome.fdsk.missing:error]: Call home for FILESYSTEM DISK MISSING

 

  • 使用 storage disk show -shelf <shelf_number> 和警报中标识的磁盘架编号来检查驱动器:

ClusterA::> storage disk show -shelf 0
                     Usable           Disk    Container   Container
Disk                   Size Shelf Bay Type    Type        Name      Owner
---------------- ---------- ----- --- ------- ----------- --------- --------
1.0.0               546.9GB     0   0 SAS     aggregate   aggr0_ClusterA-02 ClusterA-02
1.0.1               546.9GB     0   1 SAS     aggregate   aggr0_ClusterA-01 ClusterA-01
1.0.3               546.9GB     0   3 SAS     aggregate   aggr0_ClusterA-01 ClusterA-01
1.0.4               546.9GB     0   4 SAS     aggregate   aggr0_ClusterA-02 ClusterA-02
1.0.5               546.9GB     0   5 SAS     aggregate   aggr0_ClusterA-01 ClusterA-01
1.0.6               546.9GB     0   6 SAS     aggregate   aggr0_ClusterA-02 ClusterA-02
1.0.7               546.9GB     0   7 SAS     aggregate   aggr1     ClusterA-01
1.0.8               546.9GB     0   8 SAS     spare       Pool0     ClusterA-02
1.0.9               546.9GB     0   9 SAS     aggregate   aggr1     ClusterA-01
1.0.10              546.9GB     0  10 SAS     spare       Pool0     ClusterA-02
1.0.11              546.9GB     0  11 SAS     aggregate   aggr1     ClusterA-01
1.0.12              546.9GB     0  12 SAS     spare       Pool0     ClusterA-02
1.0.13              546.9GB     0  13 SAS     aggregate   aggr1     ClusterA-01
1.0.14              546.9GB     0  14 SAS     spare       Pool0     ClusterA-02
1.0.15              546.9GB     0  15 SAS     aggregate   aggr1     ClusterA-01
1.0.16              546.9GB     0  16 SAS     spare       Pool0     ClusterA-02
1.0.17              546.9GB     0  17 SAS     spare       Pool0     ClusterA-01
1.0.18              546.9GB     0  18 SAS     spare       Pool0     ClusterA-02
1.0.19              546.9GB     0  19 SAS     spare       Pool0     ClusterA-01
1.0.20              546.9GB     0  20 SAS     spare       Pool0     ClusterA-02
1.0.21              546.9GB     0  21 SAS     spare       Pool0     ClusterA-01
1.0.22              546.9GB     0  22 SAS     spare       Pool0     ClusterA-02
1.0.23              546.9GB     0  23 SAS     spare       Pool0     ClusterA-01
23 entries were displayed.

  • 上述示例中缺少驱动器 1.0.2 。

解决方法

查看磁盘缺失警报的以下可能原因:

  1. 是否正在进行维护?
  1. 检查驱动器是否实际位于磁盘架托架中
  1. 所有权是否已从分区驱动器中删除 - 错误编号 1403752
  1. 驱动器是否再次可见?
    • storage disk show -shelf <shelf_number> 第一次警报后 30 分钟左右检查。
  1. 如果上述步骤均未提供任何说明,但驱动器仍不存在,请联系 NetApp 技术支持 以获得进一步帮助。

追加信息