跳转到主内容

PSU传感器上的DS2246磁盘架OT警告

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • DS2246

问题描述

  • 在检查存储故障输出时、我们会看到以下错误:

Enclosure Status: non-critical
Channel: 0a
Shelf: 12
Shelf Type: DS2246
Product Serial Number: SHFFG1451000046
Module Type: IOM6
Temperature Sensors:
Element Status         Status Bytes  Status Descriptions  
1: OK                01,00,24,00  
2: OK                01,00,27,00  
3: OK                01,00,2E,00  
4: OK                01,00,47,00  
5: OK                01,00,30,00  
6: NONCRITICAL       03,00,58,04   OT WARNING 
7: OK                01,00,2C,00  
8: OK                01,00,2E,00

  • 我们还可以在EMS中看到以下警报:

3/14/2024 15:48:34  rpsdlxx1         ALERT         ses.status.temperatureWarning: DS2246 (S/N SHFFG1451000046) shelf 12 on channel 0a temperature warning for Temperature sensor 6: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower right power supply.
3/14/2024 15:48:34  rpsdlxx2         ALERT         ses.status.temperatureWarning: DS2246 (S/N SHFFG1451000046) shelf 12 on channel 0c temperature warning for Temperature sensor 6: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower right power supply.
3/14/2024 15:48:25  rpsdlxx1         ERROR         monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.