跳转到主内容

重复报告CPU0_Error "State assered"和"State deastered"

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • FAS8200
  • AFF A300

问题描述

  • CPU0_Error "State Asserted""State Deasserted" 并从服务处理器(SP)重复报告。 events all受影响节点上的警示LED可能会亮起。

Record 1532: Fri Mar 26 03:45:32 2021 [IPMI.notice]: a403 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1533: Fri Mar 26 03:45:39 2021 [IPMI.notice]: a503 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1534: Fri Mar 26 03:47:32 2021 [IPMI.notice]: a603 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1535: Fri Mar 26 03:47:39 2021 [IPMI.notice]: a703 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1536: Fri Mar 26 03:47:46 2021 [IPMI.notice]: a803 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1537: Fri Mar 26 03:47:53 2021 [IPMI.notice]: a903 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1538: Fri Mar 26 03:48:07 2021 [IPMI.notice]: aa03 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1539: Fri Mar 26 03:48:14 2021 [IPMI.notice]: ab03 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1540: Fri Mar 26 03:48:28 2021 [IPMI.notice]: ac03 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1541: Fri Mar 26 03:48:42 2021 [IPMI.notice]: ad03 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"

  • SP重新启动后、问题描述 仍会保留。

Record 1695: Thu Jan  1 00:00:41 1970 [IPMI.notice]: bf03 | c0 | OEM: ffff70005000 | ManufId: 150300 | SP Reset Externally
Record 1696: Thu Jan  1 00:00:41 1970 [IPMI.notice]: c003 | c0 | OEM: fcff70000000 | ManufId: 150300 | POS Register: Unexpected Reset
Record 1697: Thu Jan  1 00:00:50 1970 [IPMI.notice]: c103 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1698: Thu Jan  1 00:00:55 1970 [IPMI.notice]: c203 | 02 | EVT: 0300ffff | Fan_Override | Assertion Event, "State Deasserted"

  • system sensors show !normal 在输出中、 CPU Errorfault 处于状态。

Cluster::> sensors show -state !normal
  (system node environment sensors show)
Node Sensor
     State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- --------
------- -------
node-1
   CPU0 Error       fault
                    ERROR

  • 从SP system sensors CPU0状态为InAsserted 状态。

Sensor Name    | Current   | Unit     | Status    | LCR     | LNC     | UNC     | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
CPU0_Temp_Margin | -60.000   | degrees C  | ok      | na     | na     | -10.000   | 0.000    
In_Flow_Temp    | 21.000    | degrees C  | ok      | 0.000    | 5.000    | 50.000   | 55.000   
Out_Flow_Temp   | 34.000    | degrees C  | ok      | 0.000    | 5.000    | 65.000   | 75.000   
PCI_Slot_Temp   | 30.000    | degrees C  | ok      | 0.000    | 5.000    | 60.000   | 70.000   
Smart_Bat_Temp   | 28.000    | degrees C  | ok      | 0.000    | 5.000    | 60.000   | 70.000   
CPU0_Error     | 0x0     | discrete   | Asserted  | na     | na     | na     | na         

 

  • 这篇文章对您有帮助吗?