跳转到主内容

A900 HA互连已关闭、并出现e5a/e5b致命错误

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

    

适用场景

  • AF-A900
  • ONTAP 9.15.1P2

问题描述

EMS报告HA互连已关闭、并显示e5a/e5b致命错误。

示例:

[node-01: intr: netif.fatal.err:alert]: The network device in slot 5 encountered fatal error e5a/e5b.
[node-01: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e5a: Link down, check cable.
[node-01: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e5b: Link down, check cable.
[node-01: statd: ic.HAInterconnectDown:error]: HA interconnect: Interconnect down for 15 minutes: link0 down
[node-01: statd: callhome.hainterconnect.down:alert]: Call home for HA INTERCONNECT DOWN due to link0 down.
 
Sysconfig -ac:

sysconfig: slot 5 OK: X91146A: Dual 40/100G Ethernet T62100-CR

Sysconfig -a:

slot 5: Dual 40/100G Ethernet T62100-CR
          e5a MAC Address:   00:07:43:75:79:70 (auto-unknown-fd-down)
        e5b MAC Address:   00:07:43:75:79:78 (auto-unknown-fd-down)
        Device Type:     T6 2
        Firmware Version:   1.27.5.0