跳转到主内容

由于多磁盘错误, FlexArray 节点已重新启动

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • FlexArray
  • ONTAP 9

问题描述

  • 由于多磁盘错误, FlexArray 节点已重新启动
 
Wed Oct 27 13:52:23 [netapp: config_thread: raid.config.filesystem.disk.not.responding:notice]: File system Disk /aggr/plex0/rg2/switch:30.159L49 Shelf - Bay - [NETAPP   INF-01-00     0840] S/N [60080E50004700C0000001F8585xxxxx] UID [60080E50:004700C0:000001F8:585xxxxx:00000000:00000000:00000000:00000000:00000000:00000000] is not responding.

Wed Oct 27 13:52:23 [netapp: config_thread: cf.multidisk.fatalProblem:info]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr aggr: raid volfsm, fatal disk error in RAID group with no parity disk..  Raid type - raid0 Group name plex0/rg2 state NORMAL. 1 disk failed in the group. Disk switch:30.159L49 Shelf - Bay - [NETAPP   INF-01-00     0840] S/N [60080E50004700C0000001F8585xxxxx] UID [60080E50:004700C0:000001F8:585xxxxx:00000000:00000000:00000000:00000000:00000000:00000000] error: disk operation timed out..
 
  • 后端存储未报告任何问题
  • 网络结构已清除任何错误