适用场景

  • 离线 FLI
  • ONTAP 9.x
  • 第三方存储 

问题描述

  • 离线 FLI 迁移后,FLI 磁盘在 Ontap CLI 上显示为损坏。
  • 所有启动器均已从交换机端的分区中移除。 

AFF-C400::> storage errors show
Disk: HPE-1.14
UID: 600C0FF0:003B55EA:6FE71563:01000000:00000000:00000000:00000000:00000000:00000000:00000000
--------------------
HPE-1.14 (600c0ff0003bxxyyxyxyxyy301000000): This array LUN is an unknown device.
HPE-1.14 (600c0ff0003b5xxyyxyxyxyy301000000): This array LUN is only available on one path. Proper configuration requires two paths.
This disk is in a failed state with the outage reason "init failed". The Disk needs to be removed and replaced.

  • 作为故障排除步骤,可以使 Ontap FC 启动器端口脱机,以确保没有与第三方存储的活动连接。