跳转到主内容

在使用批处理方法进行ANDU期间、LIF迁移失败

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9.14.1P4
  • ONTAP 9.13.1P8
  • ONTAP 9.12.1P2 9.12.1P11
  • ONTAP 9.11.1P9
  • ONTAP 9.10.1P12
  • ONTAP 9.9.1P3 9.9.1P15
  • ONTAP 9.8到9.8P20
  • ONTAP 9.7P22
  • 自动化无中断升级(ANDU)
  • 批处理方法

问题描述

  • 在ANDU ONTAP升级期间、数据LIF (逻辑接口)迁移失败、导致升级过程暂停。
  • 当节点接管其配对节点时、配对节点的生命周期将根据网络接口故障转移目标规则进行迁移。
  • 在此场景中、由于配对 节点不属于数据LIF故障转移目标、因此它尝试故障转移到集群中的另一个节点。
    • 由于目标节点在升级过程中不可用、LIF迁移失败。

示例:

cluster1::> net int show -vserver test -lif lif4 -failover
  (network interface show)
     Logical      Home          Failover     Failover
Vserver  Interface     Node:Port        Policy      Group
-------- --------------- --------------------- --------------- ---------------
svm1
     lif4       cluster1-01:e0c     system-defined  test
             Failover Targets: node-04:a0a-105, node-01:a0a-105

::> cluster image show-update-progress
                                           Estimated         Elapsed   
-------------------- ----------------- --------------- ---------------  
Pre-update checks    completed                00:10:00        00:02:09
Data ONTAP updates   paused-on-error          02:34:00        02:59:26  

Details:   

Node name            Status            Status Description   
-------------------- ----------------- --------------------------------------    
node-01            waiting
node-02            completed
node-03            waiting                                                          
node-04            failed            Error: Failed to migrate data LIFs             
                                       from node "node-04".                            
                                       Action: Migrate all of the data LIFs          
                                       migrate -vserver <vserver-name> -lif
                                      <data-lif-name> -dest-node node-03" command.
node-05           waiting
node-06           completed
node-07           waiting    
          
Status: Paused-An error occurred in "Data ONTAP updates" phase.The update cannot continue until the error has been resolved.

事件日志\EMS:

Thu Apr 01 16:01:03 -0700 [node-02: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the 
cluster has been paused due to the following reason:
Node "node-03": Error: {Failed to migrate data LIFs from node "node-04".}, 
Action: {Migrate each of the data LIFs using the "network interface migrate
 -vserver  -lif  -dest-node node-03" command.}.