跳转到主内容

由于MetroCluster SDS上的NVLog传输、写入延迟较长

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • MetroCluster软件定义的存储(MCC SDS)

问题描述

  • 网络配置VXLAN后MCC SDS上的写入延迟较长
  • 在命令行界面中、使用命令QoS统计信息volume延迟show检查

cluster::> qos statistics volume latency show -node test_node1

Workload       ID    Latency    Network    Cluster       Data       Disk      QoS      NVRAM      Cloud 

------------ ------ ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- -

volume_1    12578  15426ms    1ms      0ms     0.5us      1ms    0ms    123ms        0ms  

  • EMS显示警报:
Wed Jan 17 09:01:35 +0800 [PDC-SDC-ONTAP-MCC-A-02: pha_main001: mlm.excessive.TPlatency:notice]: Average latency of 250077us on target port 5302800000030000, has exceeded 250000us
Wed Jan 17 09:02:33 +0800 [PDC-SDC-ONTAP-MCC-A-02: pha_main000: mlm.excessive.TPlatency:notice]: Average latency of 250135us on target port 5301800000040000, has exceeded 250000us