跳转到主内容

Cloud Volumes ONTAP NVlog 传输瓶颈—解决指南

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

Cloud Volumes ONTAP ( CVO )

问题描述

  • 与内部FAS/AFA相比、Cloud Volumes ONTAP在架构上存在一些差异、这可能导致ONTAP的NVLogging组件成为性能瓶颈
  • 这通常表现为写入延迟增加或写入吞吐量降低
  • 可以通过 qos statistics volume latency show 命令观察到这种情况、延迟显示在 NVRAM 列中:

Cluster::>qos statistics volume latency show
Workload            ID    Latency    Network    Cluster       Data       Disk        QoS     NVRAM
--------------- ------ ---------- ---------- ---------- ----------  ---------  ---------  ---------
-total-              -   136.49ms    99.00us    70.00us   550.00us   153.00us        0ms   136.17ms
vserver1_vol1..   4201   206.05ms   130.00us        0ms   407.88us    44.00us        0ms   205.88ms
vserver5_vol8..   7704   177.54ms   351.00us     1.00us   834.00us   114.00us        0ms   176.33ms
-total-              -   140.29ms   103.00us    75.00us   335.56us   174.00us        0ms   139.94ms
vserver1_vol1..   4201   379.03ms   127.00us        0ms   234.73us   175.00us        0ms   378.73ms
vserver5_vol8..   7704   253.02ms   309.00us     1.30us   820.00us   105.00us        0ms   251.37ms