跳转到主内容

CONAP-430498:由于PCIe链路初始化错误、A70无法访问NVMe磁盘

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

问题描述

  •  由于PCIe链路初始化错误、A70无法访问NVMe磁盘 

{}  [Node-02: SPR error: pcie.stealth.errors:debug]: params: {'pcie_errors': 'SPR:Socket1:IIO-Stack5:RPT(172,1,0): Microchip PCI-E Switch on Controller, Br[4068](174,15,0): DevStatus(Corr), CorrErr(Rcvr); '{}}
  [Node-02: kernel: nvme.link.error:error]: PCIe link initialization error for NVMe SSD in slot 7.
  [Node-02: scsi_cmdblk_strthr_admin: disk.timeout.flush.start:notice]: Aggressive timeout flush started on disk 0n.7 S/N XXXXXXXXXX. Details: Power Cycled: true Reason: Disk Spasm.
  [Node-02: scsi_cmdblk_strthr_admin: scsi.cmd.pastTimeToLive:error]: Disk device 0n.7L0: request failed after try #1: cdb 0xe2:01:0100000000000000:000000400000.
  [Node-02: config_thread: raid.disk.offline:notice]: Marking partner:Disk 0n.7 Shelf 0 Bay 7 [NETAPP   X4025S173A3T8NTE NA50] S/N [XXXXXXXXXX] UID [374A4130:58606713:00253854:00000002:00000000:00000000:00000000:00000000:00000000:00000000] offline.
  [Node-02: svc_queue_thread: cf.disk.inventory.mismatch:error]: Status of the disk ?.? (674A4130:58606713:00253854:00000002:500A0981:00000001:00000000:00000000:00000000:00000000) has recently changed or the node (Node-02) is missing the disk.
 
  • NVME disk is missed from sysconfig -a 

  6  :NetApp  X4025S173A3T8NTE NA50 3662.5GB 4160B/节(XXXXXXXX)==>缺少磁盘7
  8  :NetApp  X4025S173A3T8NTE NA50 3662.5GB 4160B/节(XXXXXXXX)