跳转到主内容

CORTP-165223:NS224磁盘架的交换机连接存储警报错误

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

问题描述

  • SAS-connect运行状况报告已降级
    ::> system health subsystem show
    Subsystem Health
    ----------------- ------------------
    SAS-connect degraded
    Environment ok
    Memory ok
    Service-Processor ok
    Switch-Health degraded
    CIFS-NDO ok
    Motherboard ok
    IO ok
    MetroCluster ok
    MetroCluster_Node ok
    FHM-Switch ok
    FHM-Bridge ok
    SAS-connect_Cluster ok


  • 接收有关磁盘架布线和路径的持久运行状况警报
    ::> system health alert show -fields alert-id,subsystem,alerting-resource-name

    node monitor alert-id alerting-resource subsystem alerting-resource-name
    ---------- --------------- ----------------------- ---------------------------- ------------- ----------------------------
    netapp-01 ethernet-switch SwitchUnreachable_Alert netapp-01-nvme1-1 Switch-Health netapp-01-nvme1-1
    netapp-01 ethernet-switch SwitchUnreachable_Alert netapp-01-nvme1-2 Switch-Health netapp-01-nvme1-2
    netapp-01 ethernet-switch SwitchUnreachable_Alert netapp-01-nvme1-3 Switch-Health netapp-01-nvme1-3
    netapp-01 node-connect NoPathToNSMB_Alert xxxxx SAS-connect Shelf 1.3
    netapp-01 node-connect NoPathToNSMB_Alert xxxxx SAS-connect Shelf 1.2
    netapp-02 node-connect SingleAdapterToShelf_Alert xxxxx SAS-connect Shelf 1.3


  • 从ONTAP端查看布线和配置时、会显示所有布线均已正确布线、节点会报告布线正确。