跳转到主内容

系统级诊断测试失败、并显示Unigen NVDIMM

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • FAS8300/8700
  • AF-A400

问题描述

  • 系统级诊断测试失败 、并在首次尝试和第二次尝试测试成功时显示Unigen NVDIMM。

第一测试:

Memory:
 dimm11  16 GB    3200 MT/s 1    Unigen 
 
Diagnostics tool for FAS8300 - Version 07.01.04
Action     Id How     Name                     Status
---------- ---- ---------- ------------------------------------------- --------------------------------
RunTest:    1 Foreground MEM:patternverify:NVDIMM           Running -------------
Error: no valid data- Slot 11
Error

第二次测试:

Diagnostics tool for FAS8300 - Version 07.01.04
Action     Id How     Name                     Status
---------- ---- ---------- ------------------------------------------- --------------------------------
RunTest:    1 Foreground MEM:patternstore:NVDIMM            Running -------------
Success

  • 在测试后和重新启动期间、系统检测到以下错误:

System will power cycle and wait NVDIMM backup
Running full memory initialization.
DIMM F0: NVDIMM in ERROR condition (status = 00000801).