适用场景

  • ONTAP 9.10及更高版本
  • SVM-DR

问题描述

具有SVM-DR目标副本的节点在更新期间因操作中断/管理启动LIF而发生暂停错误。
 
示例:
upgrademgr.update.pausedErr:error: The automated update of the cluster has been paused due to the following reason: Node abc: Error: {SAN or NVMe LIFs are currently down, potentially causing an outage when the cluster is upgraded. LIFs that are down: node1_port_a_lif1, Action: {Before upgrading, bring all SAN and NVMe LIFs up using the 'network interface modify { -data-protocol fcp|iscsi|fc-nvme|nvme-tcp } -status-admin up' command.}.
 
cluster1::*> network interface show -data-protocol iscsi
                           Logical    Status     Network            Current       Current Is
Vserver                    Interface  Admin/Oper Address/Mask       Node          Port    Home
-----------                ---------- ---------- ------------------ ------------- ------- ----
svm_1-dr
         svm_1-dr_node1_port_e0g_lif1 up/down   x.x.x.x           cluster1-01  e0g     true