跳转到主内容

运行状况监控进程cshm:ClusterSwitchConnectivity _Alert

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • 集群交换机

问题描述

  • 收到的AutoSupport通知:

Health Monitor process cshm: ClusterSwitchConnectivity_Alert 

  • 集群端口闪烁和集群交换机运行状况监控通知:

Sat May 28 08:33:43 -0400 [netapp01: intr: netif.linkDown:info]: Ethernet e1a: Link down, check cable.
Sat May 28 08:33:45 -0400 [netapp01: intr: netif.linkUp:info]: Ethernet e1a: Link up.
Sat May 28 09:11:27 -0400 [netapp01: intr: netif.linkDown:info]: Ethernet e1a: Link down, check cable.
Sat May 28 09:11:29 -0400 [netapp01: intr: netif.linkUp:info]: Ethernet e1a: Link up.
Sat May 28 09:11:30 -0400 [netapp01: vifmgr: vifmgr.portup:notice]: A link up event was received on node netapp01, port e1a.
Sat May 28 09:28:23 -0400 [netapp01: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e1a on node netapp01 has gone down unexpectedly.
Sat May 28 09:35:28 -0400 [netapp01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchConnectivity_Alert , Alerting Resource = netapp01 raised by monitor ethernet-switch
Sat May 28 09:36:26 -0400 [netapp01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: ClusterSwitchConnectivity_Alert[netapp01]

  • 端口过渡到关闭状态:

slot 1: Dual 40/100G Ethernet T62100-CR
e1a MAC Address: 00:07:43:63:24:00 (auto-unknown-fd-down)
QSFP Vendor:
QSFP Part Number:
QSFP Serial Number:

  • 固件或RCF文件升级期间可能会发生问题描述