适用场景

  • ONTAP 9
  • 磁盘架

问题描述

  • 其中一个节点报告多个磁盘为scsi.cmd.checkCondition:error"

示例:
12/12/2023  Node1      ERROR      scsi.cmd.checkCondition: Disk device 9a.01.20: Check Condition: CDB 0x28:cfd20:0080: Sense Data SCSI:aborted command -  (0xb - 0x4b 0x4 0x0)(110).
12/12/2023  Node1      ERROR      scsi.cmd.checkCondition: Disk device 9a.00.20: Check Condition: CDB 0x88:0000198efd120:00000080: Sense Data SCSI:aborted command -  (0xb - 0x4b 0x4 0x0)(15).
12/12/2023  Node1      ERROR      scsi.cmd.checkCondition: Disk device 9a.01.10: Check Condition: CDB 0x28:507d8:00d8: Sense Data SCSI:aborted command -  (0xb - 0x4b 0x4 0x0)(12).
12/12/2023  Node1      ERROR      scsi.cmd.checkCondition: Disk device 9a.01.18: Check Condition: CDB 0x88:000192dd59a8:00000080: Sense Data SCSI:aborted command -  (0xb - 0x4b 0x4 0x0)(107).

  •   我们注意到、即使更换了连接到端口9a的缆线、错误也仅在SAS端口9a上增加。