跳转到主内容

磁盘架ACP模块处于重新启动状态

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • I/O模块(IOM)
  • 备用控制路径(ACP)
  • 重新启动节点没有任何影响
  • 重新拔插IOM模块不起作用

问题描述

ONTAP 将提示警报、如下所示:
 
EMS日志:
[?] Mon Nov 28 16:39:59 +0800 [Node1: dsa_worker0: ses.status.ACPError:alert]: DS4486 (S/N xxxxx) shelf 10 on channel 0a ACP Processor error for SAS shelf ACP processor 1: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top center, on shelf module A.
 
 
ACP输出:
 
Cluster::> storage shelf acp module show -node node1
Node        Module Name     State
-----------------  -----------------  ----------------------
node1        x.x.B        active
x.x.A        rebooting
 
Cluster::> node run -node node1 acpadmin ibacp_list_all
Number of ACP modules 2
MAC         SES   Last Contact  Protocol  Assigner   Shelf       Current Inband  IOM   shelf
Address       bit   (seconds ago) Version   ACPA ID   S/N        State  ID    Type   flag
---------------------------------------------------------------------------------------------------------------
00:a0:98:d5:29:c3  01    599374    1.2.02.12  0      xxxxx1809000006  0xd   0a.00.B IOM6   0x20
00:a0:98:d5:2e:73  01    123     1.2.02.12  0      xxxxx1809000006  0x17  0a.00.A IOM6   0x20