适用场景

  • ONTAP 9
  • 集群交换机
  • AF/ FAS

问题描述

  • ClusterIfIslDownWarn_Alert 将集群交换机更换为其他型号时、ISL端口的事件日志中会报告:
Thu Feb 03 18:50:33 -0800 [Node-1: cshmd: hm.alert.raised:alert]: Alert Id = ClusterIfIslDownWarn_Alert , Alerting Resource = Switch-sw01(FOCXXXXR1HA)/Ethernet1/31 raised by monitor ethernet-switch
Thu Feb 03 18:50:33 -0800 [Node-1: cshmd: hm.alert.raised:alert]: Alert Id = ClusterIfIslDownWarn_Alert , Alerting Resource = Switch-sw01(FOCXXXXR1HA)/Ethernet1/32 raised by monitor ethernet-switch
  • 已清除为这组新集群交换机报告的警报、但未清除旧交换机的警报。
  • system cluster-switch show 命令的输出 报告了4个集群交换机、而不是2个。
  • device-discovery show命令的输出确认集群端口已连接到新的集群交换机。