跳转到主内容

重新启动时AFF A250出现"es.status.ModuleError"

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF A250
  • NS224NSM8E
  • FAS500F

问题描述

AFF A250节点重新启动、配对节点在EMS中报告以下错误
 
[Node-01: dsa_worker2: ses.status.electronicsWarn:error]: NS224NSM8E (S/N XXXXXXXXXXXXXXXX) shelf 0 on channel 0s environmental monitoring warning for SES electronics 2: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the bottom, on shelf module (B).
[Node-01: dsa_worker2: ses.status.ModuleError:alert]: NS224NSM8E (S/N XXXXXXXXXXXXXXXX) shelf 0 on channel 0s PCI switch error for PCI Switch 2: status not available; status not available. This element is on the rear of the shelf at the bottom, on shelf module (B).