跳转到主内容

scsi.cmd.checkCondition:所有磁盘出错

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

AFF/FAS

问题描述

  • EMS log 中接收以下错误

[Node-01: pmcsas_admin_0: sas.adapter.debug:info]: params: {'adapterName': '0a', 'debug_string': 'SSP_EVENT 0x34 on 0a.00.4, TAG 0x7ba4007e, INIT_TAG 0xcdb8: target reset'}
[Node-01: pmcsas_admin_0: sas.adapter.debug:info]: params: {'adapterName': '0a', 'debug_string': 'ABORT TASK on device 0a.00.4 Tag 0x7ba4007e'}
[Node-01: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.00.4: Check Condition: CDB 0x28:551af160:0018: Sense Data SCSI:aborted command - (0xb - 0x4b 0x4 0x0)(27).
[Node-01: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device 0a.00.4: request successful after retry #1/#0: cdb 0x28:551af160:0018 (28).

  • 在 SAS 适配器上看到递增的错误

Cluster:> node run -node Node-01 -command sasadmin adapter_state 0a

State for adapter channel 0a: UP
                         Invald Disprt Loss   Phy    Phy
                         DWord  Error  Sync   Reset  Change
   PHY STATE             Count  Count  Count  Prob   Count
   --------------------------------------------------------
     0 12.0 Gb/s         0      0      0      0      4
     1 12.0 Gb/s         0      0      0      0      4
     2 12.0 Gb/s         0      0      0      0      4
     3 12.0 Gb/s         41456  40043  0      0      4

  • 连接磁盘架和控制器的 SAS 线缆已更换
  • 这篇文章对您有帮助吗?