跳转到主内容

X1151A端口在ONTAP升级期间挂起

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • AFF A400
  • X1151A - 2端口100GbE智能IO QSFP28铜缆|操作

问题描述

在极少数情况下、即使网络端口的状态为up、X1151A ionic网络接口卡(NIC)上的端口也可能停止响应:

slot 3: 100G Ethernet Controller IONIC
e3a MAC Address: xx:xx:xx:xx:xx:xx (auto-100g_cr4-fd-up)
QSFP Vendor: Molex
QSFP Part Number: 112-00573
QSFP Serial Number: QSFP_serial_number
e3b MAC Address: xx:xx:xx:xx:xx:xx (auto-100g_cr4-fd-up)
QSFP Vendor: Molex
QSFP Part Number: 112-00573
QSFP Serial Number: QSFP_serial_number
Device Type: ionic
Firmware Version: 1.0.1-E-31
Serial Number: serial_number
 
  • 节点可能不会使用显示任何集群接口信息 net int show.
  • Network port show -role cluster 对于 "-" 应已启动的两个接口、显示a。

示例 

NodeA::> net int show (network interface show) Logical Status Network Current Current Is Vserver Interface Admin/Oper Address/Mask Node Port Home ----------- ---------- ---------- ------------------ ------------- ------- ---- Node1 Node2_mgmt up/up 10.6.34.54/24 Node1 e0M true
NodeA::> network port show -role cluster Warning: Unable to list entries for vifmgr on node "Node1": RPC: Couldn't make connection [from mgwd on node "Node2" (VSID: -1) to vifmgr at 169.254.212.1]. Node: Node1 Speed(Mbps) Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status --------- ------------ ---------------- ---- ---- ----------- -------- e3a Cluster - - 9000 auto/- - e3b Cluster - - 9000 auto/- - 2 entries were displayed.