适用场景

  • AFF A220
  • FAS2720
  • FAS2750
  • 意外断电

问题描述

  • 同一机箱中HA对中只有一个节点发生多个意外断电

EMS日志报告接管:

Fri Nov 25 21:49:41 MST [Cluster01-01: cf_main: cf.fsm.takeover.noHeartbeat:alert]: Failover monitor: Takeover initiated after no heartbeat was detected from the partner node.
Fri Nov 25 21:49:41 MST [Cluster01-01: cf_main: cf.fsm.stateTransit:info]: Failover monitor: UP --> TAKEOVER
Fri Nov 25 21:49:41 MST [Cluster01-01: cf_takeover: ha.takeover.stateChng:debug]: params: {'old_state': 'NOT_IN_TAKEOVER', 'new_state': 'IN_CFO_TAKEOVER'}
Fri Nov 25 21:50:06 MST [Cluster01-01: cf_takeover: callhome.reboot.takeover:error]: Call home for PARTNER REBOOT (CONTROLLER TAKEOVER)
Fri Nov 25 21:50:06 MST [Cluster01-01: cf_takeover: cf.fm.takeoverComplete:notice]: Failover monitor: takeover completed


BMC报告:

Record 1783: Tue Jan 03 21:31:37.000000 2017 [BMC.emergency]: System input power lost