跳转到主内容

控制器拉出时不会发生接管

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • 所有FAS/AFF系统
  • ONTAP 9

问题描述

客户测试控制器退出以检查接管是否正常工作。在测试期间、有时接管正常、而有时接管失败、并显示以下错误。
 
示例
cluster01::*> storage failover show
                              Takeover         
Node           Partner        Possible State Description  
-------------- -------------- -------- -------------------------------------
cluster01-01   cluster01-02   -        Unknown
cluster01-02   cluster01-01   false    Waiting for cluster01-01, Takeover
                                       is not possible: Storage failover
                                       interconnect error, NVRAM log not
                                       synchronized