跳转到主内容

Switched Cluster:已从配对集群收到崩溃数据包

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • 集群交换机

问题描述

  • 节点上的集群端口关闭

[Node-01: kernel: netif.linkDown:debug]: Ethernet e0c: Link down, check cable.
[Node-01: kernel:netif.linkDown:debug]: Ethernet e0c: Link down, check cable.
[Node-01: kernel:netif.linkDown:debug]: Ethernet e0d: Link down, check cable.
[Node-01: vifmgr:vifmgr.portdown:debug]: A link down event was received on node XXXXX,   port  e0d.
[Node-01: vifmgr:vifmgr.clus.linkdown:debug]: The cluster port e0d on node XXXXX has   gone down unexpectedly.

  • 这将触发"Pan"(管理Panic)、配对节点将执行接管

[Node-01: mcc_ic_kill_pkt_handler: sk.panic:debug]: Panic String:Received PANIC packet from partner, receiving message is (Coredump and takeoverinitiated because Connectivity, Liveliness and Availability Monitor (CLAM) hasdetermined this node is out of quorum.) in SK process mcc_ic_kill_pkt_handler onrelease 9.11.1P9 (C)

  • network port show -role cluster 将所有集群端口显示为已关闭