跳转到主内容

SwitchPowerFail_Alert—集群交换机

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP 9
  • 集群网络交换机
  • NetApp集群交换机
  • 为运行状况监控进程cshm呼叫主目录:SwitchPowerFail_Alert

问题描述

AutoSupport 消息

HA Group Notification (Health Monitor process cshm: SwitchPowerFail_Alert[Swtich Name/PowerSupply-1]) ALERT

EMS日志
  • event log show -serity *-message-name callHome*

[Node Name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm SwitchPowerFail_Alert[Switch Name/PowerSupply-1].

  • event log show -serity *-message-name hm.alge.rayed*

[netapp-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = switch name/PowerSupply raised by monitor cluster-switch

命令行
  • system运行状况警报 show -node <node name> -monitor cluster-switch -alter-id SwitchPowerFail_Alert

            Node: Reporting Node Name
          Monitor: cluster-switch
       Class of Alert: SwitchPowerFail_Alert
     Severity of Alert: Major
       Probable Cause: Power_supply_failure
Probable Cause Description: "$(cluster_switch_power.psu-name)" on switch "$(cluster_switch_power.device)" is missing or is not operational.
      Possible Effect: Power supply redundancy on switch "$(cluster_switch_power.device)" might be lost.
     Corrective Actions: 1) Ensure that the power supply units supplying power to the switch are turned on.
               2) Ensure that the power cord is securely connected to the power supply of the switch.