适用场景

  • ONTAP 9

问题描述

  • ENCLOSURE BYPASSED可在中找到 storage show fault
> storage show fault -v
Enclosure Status: non-critical
Channel: 3c
Shelf: 1
Shelf Type: DS4246
Product Serial Number: XXXXXXXXXXXX         
Module Type: IOM6
Disk Elements:
Element Status                  Status Bytes  Status Descriptions
...
 19 [Bay 19]: OK                01,13,00,00  
 20 [Bay 20]: NONCRITICAL       03,14,10,04   ENCLOSURE BYPASSED B, BYPASSED B
 21 [Bay 21]: OK                01,15,00,00  
...   
  • sysconfig -a 显示受影响的磁盘正常。

 slot 0: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C, SAS, <UP>)
  Firmware rev:       01.11.00.00
  Base WWN:           5:00a098:0014dc6:88
  Phy State:          [0] Enabled, 6.0 Gb/s
                      [1] Enabled, 6.0 Gb/s
                      [2] Enabled, 6.0 Gb/s
                      [3] Enabled, 6.0 Gb/s
  QSFP Vendor:        Molex Inc.     
  QSFP Part Number:   112-00176+A0   
  QSFP Type:          Passive Copper 0.5m ID:00
  QSFP Serial Number: 235621256
         ...
                01.19: NETAPP   X308_SMNRY03TSSA NA00 2538.5GB 512B/sect (Z297CDM7)
               01.20: NETAPP   X308_THARR03TSSM NA00 2538.5GB 512B/sect (16S3K7ZUF)
                01.21: NETAPP   X308_THARR03TSSM NA00 2538.5GB 512B/sect (16SDK6P1F)

 