跳转到主内容

Solaris FC 主机在切换 / 切回期间断开连接

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • FC
  • ONTAP 9
  • MetroCluster
  • Solaris

问题描述

FC 主机在切换 / 切回期间断开连接

  • 主机消息( Solaris ):

Apr 24 10:05:31 Solaris fctl: [ID 517869 kern.warning] WARNING: fp(0)::N_x Port with D_ID=12602, PWWN=200700a098680a8c reappeared in fabric

Apr 24 10:05:31 Solaris fctl: [ID 517869 kern.warning] WARNING: fp(2)::N_x Port with D_ID=22602, PWWN=200500a098680a8c reappeared in fabric

Apr 24 10:05:32 Solaris genunix: [ID 483743 kern.info] /scsi_vhci/disk@g600a09803830357452244c2d45734162 (sd23) multipath status: failed: path 32 fp2/disk@w200500a098680a8c,4 is offline
Apr 24 10:05:32 Solaris genunix: [ID 408114 kern.info] /scsi_vhci/disk@g600a09803830357452244c2d45734159 (sd24) offline
Apr 24 10:05:41 Solaris fmd: [ID 377184 daemon.error] SUNW-MSG-ID: ZFS-8000-FD, TYPE: Fault, VER: 1, SEVERITY: Major

  • NetApp EMS 显示启动程序已登录:

Fri Apr 24 10:05:31 CEST [NetApp_N1: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '3b' by initiator port: '21:00:00:24:ff:3e:be:27' address 0x20d00. The target virtual port is: 'NetApp FC Target Port (8324) FC_01-mc:MCC_LIF_02'.

  • 但 igroup 为空:

::> igroup show -vserver svm_mcc -igroup FC-mcc
      Vserver Name: svm_mcc
      Igroup Name: FC-mcc
        Protocol: fcp
        OS Type: solaris
Portset Binding Igroup: -
      Igroup UUID: 659941e0-d591-11ea-8555-005056a4dc7a
          ALUA: true
       Initiators: -

  • 灾难恢复配置失败 AutoSupport

Fri Apr 24 11:44:34 CEST [NetApp_N1: crs: callhome.dr.apply.failed:error]: Call home for DR CONFIG REPLICATION FAILED