适用场景

  • AF-C400
  • NS224
  • NSM100

问题描述

  • ONTAP升级后、NS224磁盘架中的一个NSM100模块无法升级、故障LED亮起。

::> storage shelf show -fields module-type ,module-fe w-revision
shelf module-type module-fw-revision
 ----- ----------- ------------------
 1.0 NSM100    0231,0231
 1.1   NSM100    0231,0210 
 1.2   NSM100    0231,0231

  • storage show fault -v 显示此磁盘架 模块  Element status 为 NOT AVAILABLE 、ACP为 NOT INSTALLED

::> run -node node-1 storage show fault -v
2 entries were acted on.

Enclosure Status: normal
Channel: 0x
Shelf: 1
Shelf Type: NS224NSM100
Module Type: NSM100

Enclosure Electronics:
Element Status            Status Bytes  Status Descriptions
  1 [NSM100 A]   : OK         01,00,01,00   REPORT
  2 [NSM100 B]   : NOT AVAILABLE   07,00,00,00    

Vendor Unique Element 85-NSM100: (ACP)
Element Status            Status Bytes  Status Descriptions
  1 [NSM100 A]   : OK         01,18,00,00   NO ACPP, INBACP
  2        : NOT INSTALLED   05,18,00,00    
  

  • 正在重置  磁盘架 模块、但无法恢复状态。