跳转到主内容

SP或BMC报告严重:由于管理网络的网络负载较高、检测信号已停止

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

问题描述

  • 节点崩溃或启动失败。
  • events all 报告Heartbeat stopped检测信号已停止

Record 1731: Wed May 06 22:18:16.800000 2020 [BMC.critical]: Heartbeat stopped
Record 1732: Wed May 06 22:18:16.830000 2020 [Trap Event.warning]: hwassist loss_of_heartbeat (30)
Record 1733: Wed May 06 22:19:05.460000 2020 [ASUP.notice]: First notification email | (HEARTBEAT_LOSS) WARNING | Send failed
Record 1734: Wed May 06 22:33:22.320000 2020 [ASUP.notice]: Reminder email | (HEARTBEAT_LOSS) WARNING | Sent

Record 1679: Thu May 12 01:04:07 2022 [SP.critical]: Heartbeat stopped
Record 1680: Thu May 12 01:07:19 2022 [ASUP.notice]: Reminder email | (REBOOT (abnormal)) WARNING | Sent

  • events all 可能会报告SP load is high