适用场景

FS4483PSM3C在AFF A800中嵌入磁盘架

问题描述

  • 节点无法确定配对节点上运行的PSM3C内部磁盘架固件的版本、反之亦然。示例

1/3/2023 10:19:30 node2 ERROR ses.mismatch.fw.version: The disk shelf modules on disk shelf 0s.0 are running two different firmware versions. Disk shelf module A is running 0140, and disk shelf module B is running .
1/3/2023 10:18:52 node1 ERROR ses.mismatch.fw.version: The disk shelf modules on disk shelf 0s.0 are running two different firmware versions. Disk shelf module A is running , and disk shelf module B is running 0140.

  • 就在这些消息之前、两个节点都会报告SES电子设备问题。示例

[node_name-01: dsa_worker2: ses.status.electronicsWarn:error]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s environmental monitoring warning for SES electronics 2: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the bottom, on shelf module (B).
[node_name-01: dsa_worker2: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch error for PCI Switch 2: status not available; status not available. This element is on the rear of the shelf at the bottom, on shelf module (B).
[node_name-01: dsa_worker1: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch error for PCI Switch 2: status not available; status not available. This element is on the rear of the shelf at the bottom, on shelf module (B).
[node_name-01: dsa_disc: ses.mismatch.fw.version:error]: The disk shelf modules on disk shelf 0s.0 are running two different firmware versions. Disk shelf module A is running 0120, and disk shelf module B is running .

[node_name-02: dsa_worker3: ses.status.electronicsWarn:error]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s environmental monitoring warning for SES electronics 1: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the top, on shelf module (A).
[node_name-02: dsa_worker3: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch error for PCI Switch 1: status not available; status not available. This element is on the rear of the shelf at the top, on shelf module (A).
[node_name-02: dsa_worker0: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch error for PCI Switch 1: status not available; status not available. This element is on the rear of the shelf at the top, on shelf module (A).
[node_name-02: dsa_disc: ses.mismatch.fw.version:error]: The disk shelf modules on disk shelf 0s.0 are running two different firmware versions. Disk shelf module A is running , and disk shelf module B is running 0120.

  • 在插槽A节点中、我们缺少PSM3C B (插槽B节点)固件版本、 sysconfig -a 反之亦然:

节点A:
    Shelf 0: FS4483PSM3E Firmware rev. PSM3E A: PSM3E B: 0140

节点B:
    Shelf 0: FS4483PSM3E Firmware rev. PSM3E A: 0140 PSM3E B: