RTC电池故障

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用于

  • FAS/AFF 平台
  • 实时时钟 (RTC) 纽扣电池

问题描述

  • 节点和机箱故障指示灯亮起,出现以下错误:

hsamcmd --fault-show-all
===============================
tag  origin  fld                    fault reason                   count  time
---- ------- ----                   -------------                   ------ -----
1   bmc    /chassis-1/controller-a          P3V3_BATT: Voltage Sensor 26 LNC         1    Wed Jun 25 10:58:10 2025
2   bmc    /chassis-1/controller-a          P3V3_BATT: Voltage Sensor 26 LCR         1    Wed Jun 25 10:58:22 2025

  • 或者,节点和机箱故障 LED 点亮,但没有明确的故障指示
  • 以下 EMS 消息,并将针对电池报告非关键故障:

Tue Sep  4 15:05:29 CEST [NODE1:monitor.chassisPower.degraded:warning]: Chassis power is degraded: RTC Battery is in WARN LOW state current voltage is 2774 mV, normal low is 2800 mV

  • SP-LATEST-IPMI log shows P3.3V Batt 为以下条件。

P3.3V Batt   warnlow  2660 mV    2537 mV    2695 mV    3307 mV    3447 mV   

或

P3.3V Batt    critlow   945 mV    2100 mV    2205 mV    3395 mV    3500 mV

  • SP-LATEST-SYSLOG 日志显示rtcWarnLowPower

BMC env_mgr[1534]: Payload EMS: EMS_monitor_rtcWarnLowPower(2660 mV) 

  • BMC events all显示P3.3V Batt is critical low。

BMC env_mgr[1461]: P3.3V Batt is critical low

  • 从 BMC/SP 显示 P3V_BAT 是以下条件:

Sensor Name    | Current   | Unit     | Status    | LCR     | LNC     | UNC     | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
P3V_BATT      | 2.840    | Volts    | nc      | 2.720    | 2.880    | 3.300    | 3.460
Or
P3V3_BATT     | 0.963    | Volts    | cr      | 2.100    | 2.205    | 3.395    | 3.500