跳转到主内容

ONTAP LUN SCSI IO挂起

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • ONTAP FC/FCoE
  • FlexPod
  • VMware ESXi 7.0 Update 2
    • 驱动程序nfnic版本4.0.63-1vmw.702.0.17867351.
  • Cisco UCS

问题描述

VMware层和Cisco UCS服务器VIC接口上的LUN访问丢失和SCSI IO中止
 
示例:
VMware日志:
NMP: nmp_ThrottleLogForDevice:: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x0. Act:NONE. cmdId.initiator=0x4538c9a1bbd8 CmdSN 0x0
VMW_SATP_ALUA: satp_alua_issueCommandOnPath:706: Path (vmhba0:C0:T1:L0) command 0xa3 failed with transient error status Transient storage condition, suggest retry. sense data: 0x6 0x29 0x0. Waiting for 20 seconds


Cisco日志:
ecom.ecom_main ecom(8:1): abort called for host 1 for exch 44a4, status 3 rx_id 0 s_stat 0x0 xmit_recvd 0x0 burst_offset 0x0 sgl_err 0x0
last_param 0x0 last_seq_cnt 0x0  tot_bytes_exp 0x4000 h_seq_cnt 0x0  exch_type 0x1 s_id 0x40086 d_id 0x40141 host_tag 0xf2 tm_req
0x2 age 180 scsi_opcode 8a wq 39 mss 800