跳转到主内容

节点报告PC电源不足严重状态

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • FAS2720
  • ONTAP 9

问题描述

  • 由于启动介质不可访问、节点B发生崩溃重新启动并过渡到Loader提示符。

PANIC: thread (swi4: clock (0)) on cpu 11 hung for 4001 milliseconds in process swi4: clock (0) on release 9.7P12 (C) on Fri Mar 7 11:05:17 JST 2025

  • 在 节点B上更换启动介质期间、 节点A 检测到磁盘架故障、节点B处于 PC INSUFFICIENT POWER 严重状态。

EMS日志:

<LR d="11Mar2025 12:31:16" n="node-01"・・・・

<ses_status_procCplxError_1

        prodChannel="DS212-12 (S/N SHXXXXXXXXXXX19) shelf 0 on channel 0b"

        typeText="Processor Complex"

        electrNumber="2"

        errorMsg="PCM on partner not installed"

        errorText=""

        locationText="This module is on the unknown location"/>

</LR>

<LR d="11Mar2025 12:40:34" n="node-01"・・・・

<monitor_shelf_fault_1

        channel="0b"/>

</LR>

<LR d="11Mar2025 12:40:34" n="node-01"・・・・

<callhome_shlf_fault_1

        subject="SHELF_FAULT"/>

存储故障

Enclosure Status: critical

Channel: 0b

Shelf: 0

Shelf Type: DS212-12

Product Serial Number: SHXXXXXXXXXXX19

Module Type: IOM12E

:

Vendor Unique Element 88-IOM12E: (PCM)

Element Status         Status Bytes  Status Descriptions

  1: OK                01,01,00,00  

  2: CRITICAL          02,01,00,01  PC INSUFFICIENT POWER

 

  • 传感器2在处理器组合件连接元件上出现错误。

环境:

Environment for channel 0a
   Number of shelves monitored: 1   enabled: yes
   Environmental failure on shelves on this channel? yes

   Channel: 0a
   Shelf: 0
   SES device path: local access: 0b.00.99
   Module type: IOM12E; monitoring is active  
   Shelf status: critical condition
   SES Configuration, shelf 0:

   Processor Complex attached element list: 1, 2 with error: 2
   SAS Expander Module installed element list: 1, 2; with error: none
   SAS Expander master module: 1

  • 两个节点均处于多路径SAS连接状态、 节点B上处于严重状态的IOM12E 似乎运行正常。
  • 更换 节点B 不会解决问题描述问题。