跳转到主内容

节点因SP HBT已停止警报而关闭

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AF-A300
  • FAS8200
  • FAS8700
  • FAS2720
  • FAS2620
  • ONTAP 9

问题描述

  • 节点关闭、并在事件日志中显示以下错误:

[Node-02: spsm_listener: sp.heartbeat.stopped:error]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 20 seconds.
[Node-02: spsm_listener: callhome.sp.hbt.missed:notice]: Call home for SP HBT MISSED
[Node-02: env_mgr: sp.ipmi.lost.shutdown:EMERGENCY]: SP heartbeat stopped and cannot be recovered. To prevent hardware damage and data loss, the system will shut down in 2 minutes.
[Node-02: spsm_listener: callhome.sp.hbt.stopped:alert]: Call home for SP HBT STOPPED

  • 在节点宕机之前,SP-LATEST-IPMI可能会报多个传感器无法正常读取:

Sensor Name        State      Current   Critical    Warning    Warning   Critical
                     Reading     Low      Low      High     High
-------------------------------------------------------------------------------------------------
Partner Status       not_available    --
PSU1 Present        not_available    --
PSU1 5V          not_available    -- mV     --      --      --      --
PSU1 12V          not_available    -- mV     --      --      --      --
PSU1 5V Curr        not_available    -- mA     --      --      --      --
PSU1 12V Curr       not_available    -- mA     --      --      --      --
PSU1 Fan 1         not_available    -- RPM    --      --      --      --
PSU1 Fan 2         not_available    -- RPM    --      --      --      --
PSU1 Inlet Temp      not_available    -- C      0 C      5 C     57 C     62 C
PSU1 Hotspot Temp     not_available    -- C      0 C      5 C     90 C     100 C
PSU2 Present        not_available    --
PSU2 5V          not_available    -- mV     --      --      --      --
PSU2 12V          not_available    -- mV     --      --      --      --
PSU2 5V Curr        not_available    -- mA     --      --      --      --
PSU2 12V Curr       not_available    -- mA     --      --      --      --
PSU2 Fan 1         not_available    -- RPM    --      --      --      --
PSU2 Fan 2         not_available    -- RPM    --      --      --      --
PSU2 Inlet Temp      not_available    -- C      0 C      5 C     57 C     62 C
PSU2 Hotspot Temp     not_available    -- C      0 C      5 C     90 C     100 C
PSU_FAN          not_available    --
Module B Expander Temp   failed       -- C      0 C      5 C     80 C     90 C
Module A Expander Temp   failed       -- C      0 C      5 C     80 C     90 C
Midplane 4 Temp      failed       -- C      0 C      5 C     47 C     52 C
Midplane 3 Temp      failed       -- C      0 C      5 C     47 C     52 C
Midplane 2 Temp      failed       -- C      0 C      5 C     47 C     52 C
Midplane 1 Temp      failed       -- C      0 C      5 C     47 C     52 C
Ambient Temp        failed       -- C      0 C      5 C     47 C     50 C
Internal Shelf       not_available    --

  • 即使在重新启动并重新拔插后、此节点仍无法启动。
  • 这篇文章对您有帮助吗?