跳转到主内容

节点关闭、配对节点触发PSU严重错误

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AF-A300
  • FAS8200
  • FAS2720
  • ONTAP 9

问题描述

  • 无法访问节点崩溃和SP。
  • 配对节点触发以下PSU错误。

HA Group Notification (Health Monitor process cphm: CriticalFruMultiFaultAlert[PSQ0A2184600020]) ALERT
HA Group Notification (CHASSIS POWER SUPPLY DEGRADED: PS 1) ERROR
HA Group Notification (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1, PSU2.) ERROR

  • 在配对节点上、PSU1和PSU2显示 BAD 来自的状态 sp-latest-ipmi

sp-latest-ipmi:
/usr/local/bin/environ -show_all
================================
Sensor Name State Current Critical Warning Warning Critical
          Reading Low    Low   High   High
-------------------------------------------------------------------------------------------------
PSU2 Bad      TRUE
PSU1 Bad      TRUE
PSU2 need     replacement NO
PSU1need replacement NO
PSU2       BAD
PSU1       BAD