跳转到主内容

将磁盘架添加到现有配置后、出现NoPathToNSMB_Alert

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

  • AFF A900、AFF A800、AFF A700、AFF A400、AFF A320
  • 按照布线最佳实践添加了新的NS224磁盘架并正常工作 
  • 存储配置会从直连存储更改为交换机连接存储
  • Cisco Nexus 3232C或9336C-x2交换机

问题描述

  • NSMANSMB模块的运行状况警报

Monitor          node-connect
Alert ID         NoPathToNSMA_Alert
Alerting Resource    01234567890123456789
Subsystem         SAS-connect
Indication Time      Sun May 08 21:34:51 2022
Perceived Severity    Major
AutoSupport Triggered   true
Probable Cause      Cable_tamper
Corrective Actions   1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
           2. Connect controller amsnapc01n01 to module A and module B of shelf 1.2.

  • 系统会定期发出和清除警报: 

::>event log show -event hm.alert*
Time                Node      Severity   Event
------------------- --------  --------   ---------------------------
4/22/2022 16:12:01  node_name-1  NOTICE     hm.alert.cleared: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
4/22/2022 15:42:00  node_name-2  ALERT      hm.alert.raised: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect

  • 重复的EMS消息:

...
[node_name-1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
[node_name-1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect

...
[node_name-2: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-2: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
[node_name-2: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-2: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect

  • system switch ethernet show输出中未列出任何存储交换机。