适用场景

  • ONTAP 9
  • CN1610
  • BES — 53248

问题描述

  • 交换机已从CN1610升级到BES-53248、并保留了原有的CN1610主机名
  • 尽管连接了新设备、但新添加的交换机仍显示为旧交换机型号

cluster-1::>system cluster-switch show
sw-1        cluster-network    172.30.32.13    CN1610
Serial Number: Unknown
Is Monitored: true
Reason: None
Software Version: 3.8.0.2
Version Source: CDP/ISDP


cluster-1::>network device-discovery show -node node-1 -protocol cdp
Node/      Local  Discovered
Protocol   Port   Device (LLDP: ChassisID) Interface         Platform
----------------- ------------------------- ----------------  ----------------
node-1/cdp
e0a    sw-1       0/1             BES-53248
e0b    sw-2       0/1              BES-53248