跳转到主内容

NSM100模块警示LED亮起

i
Knowledge Base guidance

This article may include metadata, visibility, validation state, and related support guidance.

适用场景

NS224磁盘架

问题描述

  • NSM100模块警示LED亮起
  • EMS报告了以下错误:
6/10/2022 12:49:10  node01        EMERGENCY     ses.status.fanError: NS224NSM100 (S/N SHFNC2207000227) shelf 10 on channel 0x cooling fan error for Cooling element 11: critical status; fan is off. This element is on the unknown location.
  • storage fault show -v 输出中的风扇状态失败
Fans:
Element Status         Status Bytes  Status Descriptions
1: OK                01,07,FF,26
2: OK                01,07,FF,26
3: OK                01,07,FF,26
4: OK                01,07,FF,26
5: OK                01,07,FF,26
6: OK                01,07,FF,26
7: OK                01,07,FF,26
8: OK                01,07,FF,26
9: OK                01,07,FF,26
10: OK                01,07,FF,26
11: CRITICAL          02,00,00,70   OFF, FAIL
12: OK                01,07,FF,26
13: OK                01,07,FF,26
14: OK                01,07,FF,26
15: OK                01,07,FF,26
16: OK                01,07,FF,26
17: OK                01,07,FF,26
18: OK                01,07,FF,26
19: OK                01,07,FF,26
20: OK                01,07,FF,26